Lk-U31 Dental Clinic Patient Monitor Price for Surgery

Product Details
Customization: Available
Type: Implant Equipment
Material: Plastic
Still deciding? Get samples of US$ 1150/Piece
Request Sample
Diamond Member Since 2009

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
Experienced Team
The supplier has 9 foreign trading staff(s) and 7 staff(s) with over 6 years of overseas trading experience
to see all verified strength labels (16)
  • Lk-U31 Dental Clinic Patient Monitor Price for Surgery
  • Lk-U31 Dental Clinic Patient Monitor Price for Surgery
  • Lk-U31 Dental Clinic Patient Monitor Price for Surgery
  • Lk-U31 Dental Clinic Patient Monitor Price for Surgery
  • Lk-U31 Dental Clinic Patient Monitor Price for Surgery
  • Lk-U31 Dental Clinic Patient Monitor Price for Surgery
Find Similar Products

Basic Info.

Product
Portable Dental Patient Moniter for Surgery
Temperature Workingrkin
0 ~ 40
Power Supply
100~250 (V)AC, 50/60 (Hz)
Altitude Working
-500 to 4, 600m(-1, 600 to 15, 000FT)
Altitude Transport and Storage
-500 to 13, 100m(-1, 600 to 43, 000f
Transport Package
Carton
Origin
China
HS Code
90184990
Production Capacity
10000PCS/Month

Product Description

LK-U31 Dental Clinic Patient Monitor Price for Surgery

Portable Patient Monitor performs monitoring of:
ECG  Heart Rate (HR)
  2-channel ECG waveforms
  S-T segment analysis
  Arrhythmia (optional)
RESP Respiratory Rate (RR)
  Respiration Waveform
SpO2 Oxygen Saturation (SpO2), Pulse Rate (PR)
  SpO2 Plethysmogram
NIBP Systolic Pressure (NS), Diastolic Pressure (ND), Mean Pressure (NM)
TEMP Temperature DATA
IBP IBP DATA
Portable Patient Monitor (Figure 1-1) is adaptable to adult, pediatric and neonatal usage. It can monitor
vital signals as ECG, Respiratory Rate, SpO2, NIBP, TEMP and IBP. It integrates parameter measuring
modules, display and recorder in one device, featuring in compactness, lightweight and portability.
Replaceable built-in battery facilitates transportation of patient. Large high-resolution display provides
clear view of 5 waveforms and full monitoring parameters.
The POWER switch is on the left quarter of the front panel (in Figure 1-1). The POWER indicator(in
Figure 1-1) and the BATT indicator ( in Figure 1-1) lights when the device is powered on. The
ALARM indicator flashes or lights when alarm occurs ( in Figure 1-1).The sockets of the sensors are
at the right side. The recorder socket is at the left side. Other sockets and power plug-in are at the
back.

Do not immerse the connector in any liquid. After cleaning, dry the transducer thoroughly before
storing. Slight discoloration or temporary increase of surface stickiness of the cable should not be
considered abnormal If adhesive tape residue must be removed from the transducer cable, double
seal tape remover is effective and will cause a minimum of damage to the cable if used sparingly.
Acetone, Alcohol, Ammonia and Chloroform, or other strong solvents are not recommended
because over time the vinyl cabling will be damaged by these agents.

Liquid Chemical Sterilization
Remove obvious contamination by using the cleaning procedure described previously. Select a
sterilant that your hospital or institution has found to be effective for liquid chemical sterilization
of operating room equipment. Buffered gluteraldehyed (e.g. Cidex or Hospisept) has been
found to be effective. Do not use quaternary cationic detergents such as zephiran chloride. If
the whole unit is to be sterilized, immerse the transducer but not the electrical connector into
the sterilant for the recommended sterilizing period. Be sure that the dome is removed. Then
rinse all transducer parts except the electrical connector with sterilized water or saline. The
transducer must be thoroughly dried before storing.

Gas Sterilization
For more complete asepsis, use gas sterilization.
Remove obvious contamination by using the cleaning procedure described previously. To
inhibit the formation of ethylene glycol when ethylene oxide gas is used as the disinfectant, the
transducer should be completely dry.
Follow the operating instructions provided by the manufacturer of the gas disinfectant.

Lk-U31 Dental Clinic Patient Monitor Price for SurgeryLk-U31 Dental Clinic Patient Monitor Price for Surgery
Lk-U31 Dental Clinic Patient Monitor Price for SurgeryLk-U31 Dental Clinic Patient Monitor Price for SurgeryLk-U31 Dental Clinic Patient Monitor Price for SurgeryLk-U31 Dental Clinic Patient Monitor Price for SurgeryLk-U31 Dental Clinic Patient Monitor Price for SurgeryRelated dental surgery products:
Lk-U31 Dental Clinic Patient Monitor Price for SurgeryLk-U31 Dental Clinic Patient Monitor Price for SurgeryLk-U31 Dental Clinic Patient Monitor Price for SurgeryLk-U31 Dental Clinic Patient Monitor Price for SurgeryLk-U31 Dental Clinic Patient Monitor Price for SurgeryLk-U31 Dental Clinic Patient Monitor Price for SurgeryLk-U31 Dental Clinic Patient Monitor Price for Surgery